Estimated Read Time: 8 minutes

We’ve all experienced the dreaded sound of a circuit breaker tripping in our places of business. It can be concerning and difficult to understand why it happened, not to mention how to stop it from happening again. This is especially true when a circuit breaker trips and results in commercial AC failure, leading to an incomplete air conditioning system that needs repair. That’s why we’re dedicating this post today toward understanding exactly what causes a circuit breaker trip and learning the best steps you can take if your commercial AC does fail after one has occurred. Read on to explore everything there is to know about what must be done when dealing with such matters.

The Basics of Circuit Breakers and Commercial ACs – Understanding the connections between them

Circuit breakers are vital components of commercial AC systems. They act as safety switches that protect the system from short circuits and overloads. In simple terms, when there’s an electrical fault within the AC system, the circuit breaker “trips,” interrupting the electrical flow and halting the danger.

This crucial component of the AC system prevents fires and other health hazards that can endanger your property and your employees. It is essential to understand the connections between circuit breakers and commercial ACs to ensure that your business is operating efficiently and safely. By familiarizing yourself with the basics of circuit breakers and ACs, you can make informed decisions about how to protect your business and ensure longevity of your equipment.

Common Reasons Why Circuit Breakers Trip – Knowing the common causes of circuit breaker trips in commercial AC systems

circuit breaker

Electricity is a vital necessity for commercial buildings. However, it is important to understand the reasons why circuit breakers trip in commercial AC systems to avoid potential hazards and prevent damage. Circuit breakers are designed to protect electrical circuits from overloads and short circuits, leading to tripping of the breaker. Some common causes of circuit breaker tripping include high current load, ground fault, and short circuit.

A high current load is the most common cause of circuit breaker tripping, which occurs when the amount of electricity drawn from a circuit exceeds its capacity. Ground faults and short circuits, on the other hand, occur when current travels through unintended paths, leading to overloading of the circuit. Understanding these common causes can help in troubleshooting and ensuring the safety and efficiency of commercial AC systems.

How HVAC Systems Can Cause Your Circuit Breaker to Trip – Compressor issues, refrigerant pressure, electrical short, etc.

An HVAC system can sometimes cause your circuit breaker to trip, which can be quite frustrating. There could be many reasons why this happens, ranging from compressor issues to refrigerant pressure or even an electrical short. Whatever the cause may be, understanding the problem and taking necessary precautions can prevent further inconvenience.

Electrical shorts are usually caused by insulation breakdown, which might have been caused by a faulty installation or environmental factors, such as exposure to moisture. Similarly, compressor issues can cause the circuit breaker to trip if the motor is malfunctioning or if there’s a restricted airflow in the system. To avoid these issues, it’s crucial to get your HVAC system inspected regularly and ensure that it’s installed and maintained correctly.

Amp Overload from the Compressor

If you are experiencing a circuit breaker tripping, one of the potential causes could be HVAC compressor issues. The compressor in your HVAC system is responsible for circulating refrigerant throughout your building. When the compressor motor starts to malfunction and draw too much current, it can exceed the capacity of the circuit breaker. This excess current can cause the circuit breaker to trip, which is an important safety measure that prevents electrical fires.

If you suspect that your HVAC compressor is causing a circuit breaker to trip, it is important to address the issue immediately. Ignoring the problem could lead to further electrical failures or even pose a significant fire hazard. An experienced HVAC technician can diagnose and repair the issue to ensure that your system is running properly.

Winding Issues

Issues with the compressor, such as a broken winding, can cause the circuit breaker to trip. When the compressor’s winding is broken, it creates an imbalance in the electrical flow, causing the circuit breaker to trip. In such cases, the HVAC system will not function until the issue is addressed. While a tripped circuit breaker may seem like a minor issue, it is important to have it checked by a professional to avoid any further problems. If you experience any issues with your HVAC system, it is best to seek the advice of a licensed technician to diagnose and repair the problem.

Too Much Refrigerant

When excess refrigerant is added to the system, the compressor has to work harder to compress it, which leads to an increased heat level and, ultimately, the circuit breaker will trip to prevent overheating. If you notice your circuit breaker tripping frequently, it could be that too much refrigerant has been added to your system. To ensure your HVAC system performs efficiently and reliably, it’s vital to get a professional technician to recharge the refrigerant and check its level at regular intervals. By doing so, you’ll avoid any unnecessary circuit breaker tripping and keep your HVAC system running smoothly for years to come.

Taking Action to Resolve Circuit Breaker Trips – Steps you should take if a circuit breaker trips in your commercial AC system

As a commercial building owner, a tripped circuit breaker in your AC system can be a major inconvenience. In addition to the discomfort of a hot and stuffy indoor environment, it can also disrupt productivity and potentially damage valuable equipment. Fortunately, taking action to resolve circuit breaker trips can help prevent these negative consequences.

The first step is to identify the cause of the trip, which can range from a simple overload to a more serious wiring problem. Once you know what’s causing the issue, you can take the appropriate steps to rectify it, whether that involves resetting the breaker, replacing faulty components, or calling in a professional technician for further assessment.

By taking these proactive measures, you can ensure that your commercial AC system stays running smoothly and reliably, and that your building’s occupants stay cool and comfortable even during the hottest of days.

Maintenance to Avoid Future Problems – How regular maintenance can help prevent further problems with circuit breakers 

Regular maintenance of circuit breakers is essential for preventing future problems. Circuit breakers are crucial components in electrical systems, protecting wiring and appliances from damage caused by electrical overloads. 

However, these devices can experience failures over time if they are not properly maintained. Routine maintenance can help identify issues early on, such as loose connections or corrosion, allowing for repairs before a serious problem arises. Furthermore, regular maintenance can help extend the lifespan of circuit breakers, ultimately saving on costly replacements down the line. It is highly recommended to schedule routine maintenance with a licensed electrician to ensure the safety and reliability of your electrical system.

Setting Up a Maintenance Plan – Advice on creating an effective maintenance plan to ensure future circuit breaker reliability

As an essential component of electrical systems, circuit breakers play a crucial role in ensuring the safety and reliability of equipment. However, as with all mechanical devices, they can experience wear and tear over time. That’s why setting up a maintenance plan is essential to ensure long-term circuit breaker reliability.

Creating an effective maintenance plan involves a proactive and systematic approach that includes regular inspections, testing, and cleaning. By properly maintaining circuit breakers, you can avoid costly repairs and unplanned downtime, ultimately increasing the overall efficiency and safety of your electrical system. With a well-designed maintenance plan, you can rest easy knowing that your circuit breakers are in good condition and ready to perform when you need them most.

Unforeseen circuit breaker trips in your commercial AC system can be a headache for both you and your HVAC technicians. To avoid any further complications, make sure to have regular maintenance for your commercial AC system. This way, you can spot any potential problems early and limit the chances of an unexpected circuit breaker trip. Your maintenance plan should include inspections of the AC components, such as parts, fuses, wires and connections. Additionally, it is important to take a proactive approach when dealing with circuit breakers – if a problem occurs, try to identify the source quickly and contact an experienced technician to resolve the issue instead of trying to fix it yourself.  When in doubt, always contact a professional HVAC technician that you can trust with your commercial HVAC system needs. 

Combating Commercial HVAC Problems with Donnelly Mechanical

At Donnelly Mechanical, we correct all commercial HVAC problems you experience. Please visit our website and contact us today for more information on our services or any questions you might have related to maintaining your commercial AC equipment.

Back to Blog